Mode Door Replacement - Upper
MODE DOOR REPLACEMENT - UPPERREMOVAL PROCEDURE
1. Remove the HVAC Module.
2. Remove the mode actuator screws.
3. Remove the mode actuator.
4. Remove the left temperature actuator screws.
5. Remove the left temperature actuator.
6. Remove the screws that retain the mode actuator bracket.
7. Remove the mode actuator bracket.
8. Remove the upper module case screws in order to access the door.
9. Open the module.
10. Remove the actuator cam from the door.
11. Remove the spring (1) from the upper mode door (2).
12. Remove the upper mode door.
INSTALLATION PROCEDURE
1. Install the upper mode door.
2. Attach the spring (1) to the upper mode door (2).
3. Install the actuator cam to the mode door.
4. Close the module case.
5. Install the module case screws.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten
Tighten the screws to 1.4 N.m (12 lb in).
6. Install the mode actuator and bracket.
7. Install the actuator screws.
Tighten
Tighten the screws to 1.4 N.m (12 lb in).
8. Install the left temperature actuator.
9. Install the actuator screws.
Tighten
Tighten the screws to 1.4 N.m (12 lb in).
10. Install the HVAC module.