Operation CHARM: Car repair manuals for everyone.

Air Delivery Improper

TEST DESCRIPTION

Steps 1-4:




Steps 5-7:




Steps 8-11:




Steps 12-19:




The number(s) below refer to the step number(s) on the diagnostic table.
8. Observe the Vacuum Solenoid parameters to verify that the appropriate solenoids are energized for their respective modes. In Vent mode, solenoid 3 is ON. In Defrost mode, solenoids 1 and 3 are ON-Please note that the Defrost switch should be activated in this mode. In Vent/Recirc, solenoids 3 and 4 are ON-Note that the Recirc switch should be activated in this mode. In Heater mode, solenoids 2 and 3 are ON. In Recirc mode solenoids 2, 3, and 4 are ON. In Def/Heater mode, solenoids 2 and 5 are ON.
10. Test the solenoid control circuit of the solenoid that does not click ON and OFF. Verifies that the HVAC control module is providing ground to the solenoid in the vacuum control assembly.
11. Tests if ground is constantly being applied to the vacuum control assembly.