P0140
CIRCUIT DESCRIPTIONHeated oxygen sensors (HO2S) are used for fuel control and post catalyst monitoring. Each HO2S compares the oxygen content of the surrounding air with the oxygen content of the exhaust stream. When the vehicle is first started the powertrain control module (PCM) operates in an Open Loop mode, ignoring the HO2S signal voltage when calculating the air-to-fuel ratio. The PCM supplies the HO2S with a reference, or bias, voltage of about 450 mV. The HO2S generates a voltage within a range of 0-1,000 mV that fluctuates above and below bias voltage once in Closed Loop. High HO2S voltage output indicates a rich fuel mixture; low HO2S voltage output indicates a lean mixture. Heating elements inside the HO2S minimize the time required for the sensors to reach operating temperature, and provide an accurate voltage signal. The HO2S 2 is used for post catalyst monitoring. If the PCM detects that the HO2S 2 voltage remains at or near the bias voltage amount, DTC P0140 will set.
Each HO2S 2 has the following circuits:
- HO2S 2 high signal
- HO2S 2 low signal
- HO2S 2 heater ignition 1 voltage
- HO2S 2 heater ground
CONDITIONS FOR RUNNING THE DTC
- DTCs P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0116, P0117, P0118, P0121, P0122, P0123, P0125, P0128, P0201, P0202, P0203, P0204, P0205, P0206, P0410, P0440, P0442, P0443, P0446, P0449, and P1441 are not set.
- The Engine Run Time parameter is longer than 200 seconds.
CONDITIONS FOR SETTING THE DTC
The PCM detects that the HO2S 2 signal voltage remains between 412-490 mV for more than 90 seconds.
ACTION TAKEN WHEN THE DTC SETS
- The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
- The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.
CONDITIONS FOR CLEARING THE MIL/DTC
- The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
- A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
- A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
- Clear the MIL and the DTC with a scan tool.
TEST DESCRIPTION
Steps 1-2:
Steps 3-4:
Steps 5-6:
Steps 7-8:
Steps 9-13:
The numbers below refer to the step numbers on the diagnostic table.
2. A normally functioning HO2S 2 voltage signal will fluctuate above and below the bias voltage amount. The action in the test step should result in a visible reaction from the HO2S 2 output.
4. A voltage reading other than the specified amount in this step indicates an open circuit condition in one of the signal circuits or the PCM.
5. This step inspects for an open circuit condition in the signal circuits, independent of the PCM.
7. The conditions listed in the table may contribute to the failure of the HO2S. The conditions listed apply only to this type of failure.