AIR CONDITIONING (A/C) REFRIGERANT PRESSURE SENSOR REPLACEMENT

REMOVAL PROCEDURE
1. Disconnect the electrical connection from the sensor.
2. Remove the A/C refrigerant pressure sensor.
Discard the O-ring seal.


IMPORTANT: The sensor is mounted on a service fitting. Do not discharge the system.

INSTALLATION PROCEDURE
1. Install the new O-ring seal.
2. Install the A/C refrigerant pressure sensor.


NOTE: Refer to Fastener Notice in Service Precautions.

Tighten
Tighten the sensor to 5 N.m (44 lb in).

3. Connect the electrical connection to the sensor.