Refrigerant Pressure Sensor / Switch: Service and Repair
AIR CONDITIONING (A/C) REFRIGERANT PRESSURE SENSOR REPLACEMENTREMOVAL PROCEDURE
1. Disconnect the electrical connection from the sensor.
2. Remove the A/C refrigerant pressure sensor.
Discard the O-ring seal.
IMPORTANT: The sensor is mounted on a service fitting. Do not discharge the system.
INSTALLATION PROCEDURE
1. Install the new O-ring seal.
2. Install the A/C refrigerant pressure sensor.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten
Tighten the sensor to 5 N.m (44 lb in).
3. Connect the electrical connection to the sensor.