Air Temperature Sensor ( Ambient / Intake ): Service and Repair
INTAKE AIR TEMPERATURE (IAT) SENSOR REPLACEMENTREMOVAL PROCEDURE
1. Disconnect the air cleaner duct from the air cleaner resonator.
2. Disconnect the IAT sensor harness connector.
3. While twisting the IAT sensor (4), pull the sensor from the air cleaner resonator (1).
INSTALLATION PROCEDURE
1. Press the IAT sensor (4) into the air cleaner resonator (1).
2. Connect the IAT sensor harness connector.
3. Connect the air cleaner duct to the air cleaner resonator.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten
Tighten the clamp to 5 N.m (44 lb in).