Mode Door-Lower
MODE DOOR REPLACEMENT - LOWERREMOVAL PROCEDURE
1. Remove the HVAC Module.
2. Remove the mode actuator screws.
3. Remove the mode actuator.
4. Remove the left temperature actuator screws.
5. Remove the left temperature actuator.
6. Remove the screws that retain the mode actuator bracket.
7. Remove the mode actuator bracket.
8. Remove the upper module case screws in order to access the door.
9. Open the module.
10. Remove the actuator cam from the door.
11. Remove the mode door.
INSTALLATION PROCEDURE
1. Install the mode door.
2. Install the actuator cam to the mode door.
3. Close the module case.
NOTE: Refer to Fastener Notice in Service Precautions.
4. Install the module case screws.
Tighten
Tighten the screws to 1.4 N.m (12 lb in).
5. Install the mode actuator and bracket.
6. Install the mode actuator screws.
Tighten
Tighten the screws to 1.4 N.m (12 lb in).
7. Install the left temperature actuator.
8. Install the actuator screws.
Tighten
Tighten the screws to 1.4 N.m (12 lb in).
9. Install the HVAC module.