Inflatable Restraint Instrument Panel Module Replacement
INFLATABLE RESTRAINT INSTRUMENT PANEL MODULE REPLACEMENTRemoval Procedure
Caution: Refer to SIR Inflator Module Handling and Storage Caution in Service Precautions.
1. Disable the SIR system. Refer to SIR Disabling and Enabling Zone 5. SIR Disabling and Enabling Zone 5
2. Remove the instrument panel (I/P) trim pad.
3. Disconnect the I/P module connector (2).
4. Remove the I/P module retaining nuts (3).
5. Remove the I/P module retaining bolts (4).
6. Remove the inflatable restraint I/P module (1).
7. Fully deploy the module before disposal. If the module was replaced under warranty, fully deploy and dispose of the module after the required retention period.
Installation Procedure
1. Install the inflatable restraint I/P module (1).
NOTICE: Refer to Fastener Notice in Service Precautions.
2. Install the I/P module retaining nuts (3).
Tighten
Tighten fasteners to 45 N.m (33 Ib. ft).
3. Install the I/P module retaining bolts (4).
Tighten
Tighten fasteners to 9.5 N.m (84 Ib. in).
4. Connect the I/P module connector (2).
5. Install the I/P trim pad.
6. Enable the SIR system. Refer to SIR Disabling and Enabling Zone 5. SIR Disabling and Enabling Zone 5