Generator Bracket Replacement (Second Design)
Generator Bracket Replacement (Second Design)REMOVAL PROCEDURE
1. Disconnect the negative battery cable.
2. Rotate the drive belt tensioner counter clockwise.
3. Remove the generator.
4. Remove the drive belt tensioner bolt.
5. Remove the drive belt tensioner.
6. Remove the drive belt idler pulley bolt.
7. Remove the drive belt idler pulley.
8. Remove the generator bracket bolts.
9. Remove the generator bracket.
INSTALLATION PROCEDURE
1. Install the generator bracket.
2. Install the generator bracket bolts.
NOTE: Refer to Fastener Notice in Service Precautions. Fastener Notice
Tighten
Tighten the bolts in sequence to 50 N.m (37 lb ft).
3. Install the drive belt tensioner.
4. Install the drive belt tensioner bolt.
Tighten
Tighten the bolt to 50 N.m (37 lb ft).
5. Install the drive belt idler pulley.
6. Install the drive belt idler pulley bolt.
Tighten
Tighten the bolt to 50 N.m (37 lb ft).
7. Install the generator.
8. Rotate the drive belt tensioner counter clockwise.
9. Connect the negative battery cable.