B1428
DTC B1428CIRCUIT DESCRIPTION
The body control module (BCM) controls the Ignition 1 (IGN 1) relay. The contacts of the IGN 1 relay deliver a B+ signal to the following components:
- The ABS Function
- The AC compressor relay
- The Crank relay
- The HVAC control head
- The IPC
- The PCM
- The SDM
- The Transmission solenoids
The BCM will energize the IGN 1 relay when the vehicle is in the RUN or CRANK power mode. The BCM supplies a B+ signal to the relays control circuit to energize it. The relays control circuit receives it's ground from G113. If a short or circuit malfunction takes place in the IGN 1 control circuit the BCM will set a B1428 and the relay will not energize.
CONDITIONS FOR RUNNING THE DTC
The Ignition switch is in the RUN or CRANK position.
CONDITIONS FOR SETTING THE DTC
- A DTC B1428 sets when the BCM detects a short to ground in the IGN 1 relay control feed circuit when It is trying to energize the IGN 1 relay.
- A DTC B1428 sets when the BCM detects an open in the IGN 1 relay control feed circuit when It is trying to energize the IGN 1 relay.
- The conditions above must be present for more than 0.3 seconds.
ACTION TAKEN WHEN THE DTC SETS
The BCM stores DTC B1428 in memory.
CONDITIONS FOR CLEARING THE DTC
- A short to ground or a malfunction in the IGN 1 relay control feed circuit is no longer detected by the BCM.
- A history DTC B1428 will clear after the modules ignition counter reaches the reset threshold, without a repeat of the malfunction.
DIAGNOSTIC AIDS
- If the DTC B1428 is a history DTC, the fault may be intermittent.
- The following conditions may cause an intermittent malfunction to occur:
- An intermittent short to ground in the IGN 1 relay control feed circuit
- The IGN 1 relay coil is shorted to ground internally
- The BCM is shorted to ground internally
TEST DESCRIPTION
Steps 1 - 3:
Steps 4 - 13:
The numbers below refer to the step numbers on the diagnostic table.
2. Listen for an audible click when the IGN 1 relay operates. Command both the ON and OFF states. Repeat the commands as necessary.
3. Verifies that the BCM is providing voltage to the IGN 1 relay.
4. Tests for an open in the ground circuit to the IGN 1 relay.
5. Tests if voltage is constantly being applied to the IGN 1 relay.