A/C Line/Tube Connector
A/C LINE/TUBE CONNECTOR REMOVAL/REPLACEMENTTOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging.
2. Locate the A/C coupling assembly's locking tab access slots.
IMPORTANT: When separating the A/C coupling assembly, apply light pressure between the two halves of the coupling to prevent the locking tabs from reengaging.
3. Carefully insert a small flat bladed screwdriver into the first locking tab access slot and gently lift the locking tab to release the lock.
4. Carefully insert a small flat bladed screwdriver into the second locking tab access slot and gently lift the locking tab to release the lock.
5. Open and remove the A/C coupling assembly from the A/C refrigerant component.
INSTALLATION PROCEDURE
IMPORTANT: Inspect the A/C coupling assembly locking tabs for damage or wear. Replace the A/C coupler assembly if any conditions exist.
1. Install the A/C coupling assembly to the A/C refrigerant component.
IMPORTANT: Ensure that the A/C coupling assembly is latched securely to the A/C refrigerant component.
2. Close the A/C coupling assembly.
3. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
4. Leak test the fittings of the component using J 39400-A.