Backup Lamp: Description and Operation
BACKUP LAMPSThe CHMSL/BACKUP Fuse in the I/P fuse block supplies battery positive voltage to the BCM. When the driver places the gear selection into the REVERSE position, the power-train control module (PCM) sends a class 2 message to the BCM. The message indicates that the gear selector lever is in the REVERSE position. The BCM then applies battery positive voltage from the CHMSL/BACKUP Fuse supply circuit to the backup lamps voltage supply circuit. Ground for the backup lamps is supplied from G302.