P0341
DTC P0341CIRCUIT DESCRIPTION
This ignition system does not use a conventional camshaft position (CMP) sensor that detects valve train position. The ignition control module (ICM) detects when #1 or #3 cylinder has fired on the compression stroke using sensing circuitry integrated within each coil. The sensing circuit detects the polarity and the strength of the secondary voltage output. The higher output is always at the event cylinder. The ICM sends a camshaft position signal to the powertrain control module (PCM) based on the voltage difference between the event and waste cylinder firing energy. This system is called compression sense ignition. By monitoring the camshaft position and crankshaft position signals the PCM can accurately time the operation of the fuel injectors. If the PCM receives an intermittent CMP signal from the ICM then the CMP Resync Counter on the scan tool will increment. When the PCM cannot use the information from the CMP signal, a DTC will set. If the PCM detects too many CMP Resyncs within a calibrated amount of time, DTC P0341 will set.
CONDITIONS FOR RUNNING THE DTC
The engine is running.
CONDITIONS FOR SETTING THE DTC
The PCM detects more than 30 CMP Resync counts in a 256-second window when MAP is more than 55 kPa.
ACTION TAKEN WHEN THE DTC SETS
- The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
- The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.
CONDITIONS FOR CLEARING THE MIL/DTC
- The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
- A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
- A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
- Clear the MIL and the DTC with a scan tool.
DIAGNOSTIC AIDS
- An intermittent fault in the CKP circuits may cause the PCM to resync the cam and may set this DTC. If the PCM is resyncing the camshaft, the CMP Resync Counter on the Scan tool will increment with the engine running.
- An intermittent short to voltage on the camshaft position signal can set this DTC. A direct short to voltage on the camshaft position signal circuit will set P0340, as there will be no change in the camshaft position signal input.
- Electromagnetic interference (EMI) may also set DTC P0341. Inspect the wiring harness for damage. If the harness appears to be OK, observe the CMP resync counter on the scan tool while moving connectors and wiring harnesses related to the camshaft position signal. If the CMP resync counter still does not count, while observing the scan tool, operate any non-engine related electrical components on the vehicle. A change in display will indicate the location of the malfunction.
If this DTC is determined to be intermittent, refer to Intermittent Conditions. Diagnostic Strategies
TEST DESCRIPTION
Steps 1-10:
The numbers below refer to the step numbers on the diagnostic table.
3. This step determines if DTC P0341 is the result of a hard malfunction or an intermittent condition.
4. The counter should stop incrementing with the camshaft position signal circuit disconnected and set DTC P0340. If the counter still increments, this indicates that the PCM is malfunctioning.
5. A faulty electrical connection in the camshaft position signal circuit can cause the CMP Resync Counter to increment. Anytime a faulty electrical connection is present, the CMP Reference Activity counter will stop incrementing.