Quick Connect Fitting(S) Service (Plastic Collar)
QUICK CONNECT FITTING(S) SERVICE (PLASTIC COLLAR)
TOOLS REQUIRED
- EN-46843 Tool Set, Quick Connect Fitting Release Tool
- J 37088-A Tool Set, Fuel Line Quick Connect Separator
REMOVAL PROCEDURE
1. Before you service any fuel system connection, relieve the fuel system pressure Refer to the Fuel Pressure Relief Procedure.
2. Grasp both sides of the quick connect fitting and twist 1/4 turn in each direction in order to loosen any dirt.
3. Remove any dirt, dust, or other foreign material from the quick connect fitting with compressed air.
CAUTION: Wear safety glasses when using compressed air in order to prevent eye injury.
4. Squeeze the release tabs on the plastic retainer.
5. Pull the quick connect fuel fitting apart. Use a shop towel to catch any remaining fuel that may leak from the fuel line and the fitting.
INSTALLATION PROCEDURE
1. Apply a few drops of clean engine oil to the end of the male fuel pipe.
CAUTION: Always apply a few drops of clean engine oil to the male pipe ends before connecting the fuel pipe fittings in order to reduce the risk of fire and personal injury. This will ensure proper reconnection and prevent a possible fuel leak. During normal operation, the O-rings located in the female connector will swell and may prevent proper reconnection if not lubricated.
2. Insert the male fuel pipe into the quick connect fitting.
3. Push both sides of the quick connect fitting together until the fitting clicks.
4. Pull and push repeatedly on both sides of the quick connect fitting in order to ensure that the connection is secure.