Instrument Panel Module Replacement
INFLATABLE RESTRAINT INSTRUMENT PANEL MODULE REPLACEMENT
REMOVAL PROCEDURE
1. Disable the SIR system. Refer to SIR Disabling and Enabling Zone 5.
CAUTION:
- Refer to SIR Caution in Service Precautions.
- Refer to SIR Inflator Module Handling and Storage Caution in Service Precautions.
2. Remove the instrument panel (I/P) compartment.
3. Remove the connector position assurance (CPA) from the inflatable restraint I/P module yellow 2-way connector (2).
4. Disconnect the inflatable restraint I/P module yellow 2-way connector (2).
5. Disconnect the module harness from the from the fuse block bracket.
6. Remove the inflatable restraint I/P module screws (3).
7. Remove the inflatable restraint I/P module (1).
INSTALLATION PROCEDURE
1. Make sure the module harness is routed correctly. Install the inflatable restraint instrument panel (I/P) module (1).
2. Install the screws (3) that secure the inflatable restraint I/P module.
Tighten the screws to 10 Nm (89 lb in).
NOTE: Refer to Fastener Notice in Service Precautions.
3. Connect the module harness to the fuse block bracket.
4. Connect the inflatable restraint I/P module yellow 2-way connector (2).
5. Install the CPA to the inflatable restraint I/P module yellow 2-way connector (2).
6. Install the I/P compartment.
7. Enable the SIR system. Refer to SIR Disabling and Enabling Zone 5.