Generator Bracket Replacement



GENERATOR BRACKET REPLACEMENT

REMOVAL PROCEDURE
1. Disconnect the negative battery cable.




2. Rotate the drive belt tensioner counter clockwise.
3. Remove the generator.




4. Remove the drive belt tensioner bolt.
5. Remove the drive belt tensioner.
6. Remove the drive belt idler pulley bolt.
7. Remove the drive belt idler pulley.




8. Remove the generator bracket bolts.
9. Remove the generator bracket.

INSTALLATION PROCEDURE




1. Install the generator bracket.
2. Install the generator bracket bolts.

Tighten the bolts in sequence to 50 Nm (37 lb ft).

NOTE: Refer to Fastener Notice in Service Precautions.




3. Install the drive belt tensioner.
4. Install the drive belt tensioner bolt.

Tighten the bolt to 50 Nm (37 lb ft).

5. Install the drive belt idler pulley.
6. Install the drive belt idler pulley bolt.

Tighten the bolt to 50 Nm (37 lb ft).




7. Install the generator.
8. Rotate the drive belt tensioner counter clockwise.
9. Connect the negative battery cable.