Inflatable Restraint Instrument Panel Module Replacement
INFLATABLE RESTRAINT INSTRUMENT PANEL MODULE REPLACEMENT
REMOVAL PROCEDURE
1. Disable the SIR system. Refer to SIR Disabling and Enabling Zone 5 in Restraint Systems.
CAUTION:
- Refer to SIR Inflator Module Handling and Storage Caution in Service Precautions.
- Refer to SIR Caution in Service Precautions.
- A deployed dual stage inflator module will look the same whether one or both stages were used. Always assume a deployed dual stage inflator module has an active stage 2. Improper handling or servicing can activate the inflator module and cause personal injury.
2. Remove the I/P trim pad.
3. Remove the wire harness connector from the inflatable restraint I/P module.
4. Remove the bolts from the inflatable restraint I/P module and discard the bolts.
5. Remove the inflatable restraint I/P module.
INSTALLATION PROCEDURE
1. Install the inflatable restraint I/P module.
2. Install new bolts to the inflatable restraint I/P module.
NOTE: Refer to Fastener Notice in Service Precautions.
IMPORTANT: Use new bolts on the restraint module.
Tighten the bolts to 10 N.m (89 lb in).
3. Install the wire harness connector to the inflatable restraint I/P module.
4. Install the I/P trim pad.
5. Enable the SIR system. Refer to SIR Disabling and Enabling Zone 5 in Restraint Systems.
6. Deploy the old module before disposal. If the module was replaced under warranty, fully deploy and dispose of the module after the required retention period. Refer to Pretensioner Handling and Scrapping.