Procedures
MODE VALVE ASSEMBLY REPLACEMENT
REMOVAL PROCEDURE
1. Remove the HVAC module assembly.
2. Remove the lower center floor air outlet duct.
3. Remove the upper center floor air outlet duct screws.
4. Remove the upper center floor air outlet duct.
5. Remove the mode actuator screws.
6. Remove the mode actuator.
7. Drill out the mode valve assembly heat stakes.
8. Remove the valve assembly screws.
9. Remove the valve assembly.
NOTE: Do not tamper, adjust or disassemble the mode valve assembly. The proper setting of the pretensions on the springs is critical to the film valve function.
INSTALLATION PROCEDURE
1. Install the valve assembly.
2. Install the valve assembly screws.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the screws to 1.5 N.m (13 lb in).
3. Install the mode actuator.
4. Install the mode actuator screws.
Tighten the screws to 1.5 N.m (13 lb in).
5. Install the upper center floor air outlet duct.
6. Install the upper center floor air outlet duct screws.
Tighten the screws to 1.5 N.m (13 lb in).
7. Install the lower center floor air outlet duct.
8. Install the HVAC module assembly.