Refrigerant Pressure Sensor / Switch: Service and Repair
AIR CONDITIONING (A/C) REFRIGERANT PRESSURE SENSOR REPLACEMENT
TOOLS REQUIRED
J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Remove the refrigerant pressure sensor wire harness connector.
IMPORTANT: Refrigerant recovery is not required.
2. Remove the refrigerant pressure sensor.
3. Remove and discard the O-ring.
INSTALLATION PROCEDURE
1. Install a new O-ring.
2. Install the refrigerant pressure sensor.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten to 5 N.m (44 lb in).
3. Install the refrigerant pressure sensor wire harness connector.
4. Leak test the fittings using the J 39400-A.