Starter Solenoid Clicks, Engine Does Not Crank
STARTER SOLENOID CLICKS, ENGINE DOES NOT CRANK
TEST DESCRIPTION
Step 1 - Step 8:
The numbers below refer to the step numbers on the diagnostic table.
4. When testing the circuit for a high resistance ensure to use the voltage drop test in the Circuit Testing procedure. If the circuit has more than a 0.5-volt drop when the starter is engaged, then there is a high resistance.
5. When testing the circuit for a high resistance ensure to use the voltage drop test in the Circuit Testing procedure. If the circuit has more than a 0.5-volt drop when the starter is engaged, then there is a high resistance. Ensure when testing the engine ground to battery to connect the engine ground lead to the base of the starter.