HVAC System - Manual
DTC B0269
CIRCUIT DESCRIPTION
The HVAC control module controls the HVAC actuators to regulate the airflow through the HVAC system. Each actuator is a 2 wire bi-directional electric motor. Two control circuits enable the actuator to operate. The control circuits use either a 0 or 12-volt value to co-ordinate the actuator movement. When the actuator is at rest, both control circuits have a value of 0 volts. In order to move the actuator, the HVAC control module grounds the appropriate control circuit for the commanded direction. The HVAC control module reverses the polarity of the control circuits to move the actuator in the opposite direction.
The HVAC control module determines the door position by counting motor pulses on one of the control circuits. The HVAC control module converts the pulses to counts with a range of 0-255 counts.
When a calibration or recalibration procedure is performed, the HVAC control module calculates the door travel range. The HVAC control module compares the total number of pulses to calibrated limits. If the total pulse count is less than or equal to the maximum calibrated limited and more that or equal to the minimum calibrated limit, then the calibration is considered successful.
- Air Flow Control 3 Circuit Range/Performance refers to the mode actuator.
- Air Flow Control 7 Circuit Range/Performance refers to the recirculation actuator.
- Temperature Control 2 Circuit refers to the air temperature actuator.
DTC DESCRIPTORS
This diagnostic procedure supports the following DTCs:
- DTC B0249 Air Flow Control 3 Circuit Range/Performance
- DTC B0269 Air Flow Control 7 Circuit Range/Performance
- DTC B0419 Temperature Control 2 Circuit
CONDITIONS FOR RUNNING THE DTC
The HVAC control module has completed 2 calibration/recalibration events of the actuators.
CONDITIONS FOR SETTING THE DTC
DTC P0560 is not set.
ACTION TAKEN WHEN THE DTC SETS
- The HVAC control module will substitute a default range value.
- The HVAC control module will no longer issue commands to the actuator if its run timer expires during the calibration/recalibration event.
The HVAC control module will substitute a default range value.
CONDITIONS FOR CLEARING THE DTC
- The DTC will become history if the HVAC control module no longer detects a failure.
- The history DTC will clear after 100 fault free ignition cycles.
- The DTC can be cleared with a scan tool.
DIAGNOSTIC AIDS
- Inspect the appropriate actuator door and actuator for the following conditions:
- A misaligned actuator
- Broken or binding linkages or actuator door
- Obstruction that prevents the actuator door from operating within its full range of motion
- Missing seals to the actuator door
- Misaligned seals to the actuator door
TEST DESCRIPTION
Steps 1 - 9:
Step 10:
The numbers below refer to the step numbers on the diagnostic table.
3. This step drives the actuator in one direction. The actuator shaft will not move if the actuator door is already in the position you are attempting to drive it to.
4. This step drives the actuator in the opposite direction.