Accessory Power Receptacle Replacement - 115 Volt AC - Instrument Panel (I/P)
ACCESSORY POWER RECEPTACLE REPLACEMENT - 115 VOLT AC - INSTRUMENT PANEL (I/P)
REMOVAL PROCEDURE
1. Disconnect the negative battery cable.
2. Using a flat bladed tool, disengage the 3 upper clips (1) and the 2 lower clips (4) on the accessory power receptacle bezel (3).
3. Disconnect the electrical connector.
4. Disengage the 2 clips (1) on the accessory power receptacle (2).
5. Remove the accessory power receptacle (2) from the bezel (3).
INSTALLATION PROCEDURE
1. Install the accessory power receptacle (2) to the bezel (3), by pushing in until the tabs lock in.
2. Connect the electrical connector.
3. Gently install the accessory power receptacle trim bezel (3) by pressing into place until the upper tabs (1) and lower tabs (4) are fully seated.
4. Connect the negative battery cable.