Removal Procedure
1. Remove the air cleaner assembly.
2. Remove the air conditioning (A/C) line push pin retainer and reposition the line out of the way.
3. Loosen the bank 1 intake camshaft position (CMP) actuator solenoid valve bolt enough to disconnect the engine wiring harness electrical connector from the CMP actuator solenoid valve.
4. Disconnect the engine wiring harness electrical connector (7) from the CMP actuator solenoid valve.
5. Remove the CMP actuator solenoid valve bolt.
6. Remove the CMP actuator solenoid valve.
7. Inspect the CMP actuator solenoid valve seal and replace as necessary.
Installation Procedure
1. Inspect the CMP actuator solenoid valve seal for damage. Replace the seal if necessary.
2. Install the CMP actuator solenoid valve.
3. Loosely install the CMP actuator solenoid valve bolt.
4. Connect the engine wiring harness electrical connector (7) to the bank 1 intake CMP actuator solenoid valve.
Notice: Refer to Fastener Notice.
5. Tighten the CMP actuator solenoid valve bolt.
Tighten the bolt to 10 Nm (89 lb in).
6. Position the A/C line and install the push pin retainer.
7. Install the air cleaner assembly.