Operation CHARM: Car repair manuals for everyone.

Recirculation Door Replacement



Recirculation Door Replacement

Removal Procedure

1. Remove the HVAC module assembly.
2. Remove the recirculation housing retaining screws.




3. Remove the recirculation housing from the HVAC module assembly.
4. Remove the screws from the recirculation actuator.
5. Remove the recirculation actuator.

Installation Procedure




1. Align the retaining tabs and install the recirculation housing to the HVAC module assembly.

Notice: Refer to Fastener Notice in Service Precautions.

2. Install the recirculation housing screws.

Tighten the screws to 1.5 N.m (13 lb in).

3. Align the slots on the recirculation actuator to the slots on the recirculation door shaft.
4. Install the recirculation actuator on to the recirculation door shaft.
5. Install the recirculation actuator screws.
6. Tighten the recirculation actuator screws.

Tighten the screws to 1.5 N.m (13 lb in).

7. Install the HVAC module assembly.