Generator Replacement (RPO LS4)
Generator Replacement (RPO LS4)
Removal Procedure
1. Disconnect the negative battery cable.
2. Remove the engine sight shield.
3. Remove the drive belt.
4. Disconnect the generator electrical connector (2).
5. Position aside the protective boot (1) from the generator output BAT terminal for access.
6. Remove the generator output BAT terminal nut (4) and remove the positive battery lead (3) from the generator.
7. Remove the generator bolts and generator.
Installation Procedure
Notice: Refer to Fastener Notice.
1. Install the generator and bolts.
Tighten the bolts to 50 N.m (37 lb ft).
2. Install the positive battery lead (3) and generator output BAT terminal nut (4) to the generator.
Tighten the nut to 20 N.m (15 lb ft).
3. Position the protective boot (1) to the generator output BAT terminal.
4. Connect the generator electrical connector (2).
5. Install the drive belt.
6. Install the engine sight shield.
7. Connect the negative battery cable.