Backup Lamp Switch: Service and Repair
Backup Lamp Switch Replacement
Removal Procedure
Notice: When removing or installing the backup lamp switch, do not use an open end wrench. Use only a socket in order to avoid damage to the switch assembly.
1. Disconnect the backup lamp connector.
2. Remove the backup light switch assembly.
Installation Procedure
Notice: When removing or installing the backup lamp switch, do not use an open end wrench. Use only a socket in order to avoid damage to the switch assembly.
Notice: Refer to Fastener Notice.
1. Install the backup light switch with a new gasket.
Tighten the switch to 40 N.m (30 lb ft).
2. Connect the backup lamp connector.