Power Outlet Receptacle Switch Replacement
POWER OUTLET RECEPTACLE SWITCH REPLACEMENT
REMOVAL PROCEDURE
1. Disconnect the negative battery cable.
2. Using a flat-bladed tool, disengage the 3 upper clips (1) and the 2 lower clips (4) on the accessory power receptacle switch bezel (3).
3. Disconnect the electrical connector.
4. Disengage the 2 clips (1) on the accessory power receptacle switch (2).
5. Remove the accessory power receptacle switch (5) from the bezel (3).
INSTALLATION PROCEDURE
1. Install the accessory power receptacle switch (5) to the bezel (3), by pushing in until the tabs lock in.
2. Connect the electrical connector.
3. Gently install the accessory power receptacle switch bezel (3) by pressing into place until the upper tabs (1) and lower tabs (4) are fully seated.
4. Connect the negative battery cable.