Service Port HVAC: Service and Repair
Service Ports Replacement
Tools Required
J 39037 Charge Valve Octagon Socket
Removal Procedure
1. Remove the service port cap.
2. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging (Refrigerant Recovery and Recharging) .
3. Use the J 39037 to remove the service port.
Installation Procedure
1. Replace the O-ring. Refer to O-Ring Replacement (O-Ring Replacement) .
Notice: Refer to Fastener Notice (Fastener Notice) .
2. Install the service port valve.
Tighten the valve to 11 N.m (98 lb in).
3. Evacuate and charge the system. Refer to Refrigerant Recovery and Recharging (Refrigerant Recovery and Recharging) .
4. Leak test the A/C service port. Refer to Leak Testing (Leak Testing) .
5. Install the service port cap.