Air Flow Meter/Sensor: Service and Repair
Mass Airflow Sensor/Intake Air Temperature Sensor Replacement
Removal Procedure
1. Remove the air intake duct. Refer to Air Cleaner Resonator Outlet Duct Replacement (Service and Repair) .
2. Disconnect the mass air flow (MAF)/intake air temperature (IAT) sensor electrical connector (2).
3. Remove the MAF/IAT sensor bolts.
4. Remove the MAF/IAT sensor from the air cleaner housing.
5. Remove the MAF/IAT sensor seal, if necessary.
Installation Procedure
1. Install the MAF/IAT sensor seal, if necessary.
2. Install the MAF/IAT sensor to the air cleaner housing.
Notice: Refer to Fastener Notice (Fastener Notice) .
3. Install the MAF/IAT sensor bolts.
Tighten the bolts to 10 N.m (89 lb in).
4. Connect the MAF/IAT sensor electrical connector (2).
5. Install the air intake duct. Refer to Air Cleaner Resonator Outlet Duct Replacement (Service and Repair) .