Refrigerant Pressure Sensor / Switch: Service and Repair
Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement
Special Tools
J 39400-A Halogen Leak Detector
Removal Procedure
Note: Refrigerant recovery is not required.
1. Remove the refrigerant pressure sensor wire harness connector.
2. Remove the refrigerant pressure sensor.
3. Remove and discard the O-ring.
Installation Procedure
1. Install a new O-ring. Refer to Air Conditioning O-Ring Seal Replacement Air Conditioning O-Ring Seal Replacement.
Caution: Refer to Fastener Caution Fastener Caution.
2. Install the refrigerant pressure sensor and tighten to 5 Nm (44 lb in).
3. Install the refrigerant pressure sensor wire harness connector.
4. Leak test the fittings using the J 39400-A .