Operation CHARM: Car repair manuals for everyone.

Daytime Running Lamps Malfunction




Daytime Running Lamps Malfunction

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions Diagnostic Procedure Instructions provides an overview of each diagnostic category.

Diagnostic Fault Information






Circuit/System Description

The ambient light sensor is used to monitor outside lighting conditions. The ambient light sensor provides a voltage signal that will vary between 0.2 and 4.9 volts depending on outside lighting conditions. The body control module (BCM) provides a low reference ground and 5-volt reference signal to the ambient light sensor. The BCM monitors the ambient light sensor signal circuit to determine if outside lighting conditions are correct for either daytime running lights (DRL) or automatic lamp control (ALC) when the headlamp switch is in the AUTO position. In daylight conditions, the BCM will command the DRLs ON by applying ground to the DRL relay control circuit. When the BCM applies ground to the relay control circuit, the DRL relay coil energizes causing the relay switch contacts to close. With the DRL relay switch contacts closed, battery voltage flows through the DRL fuse to the left and right low beam headlamp control circuits illuminating the low beam headlamps. Any function or condition that turns on the headlamps will cancel DRL operation.

Reference Information
Schematic Reference

Headlights/Daytime Running Lights (DRL) Schematics Headlights/Daytime Running Lights (DRL) Schematics
Connector End View Reference

Component Connector End Views Connector End Views By Name
Description and Operation

Exterior Lighting Systems Description and Operation Exterior Lighting Systems
Electrical Information Reference

* Circuit Testing Circuit Testing
* Connector Repairs Connector Repairs
* Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections
* Wiring Repairs Wiring Repairs

Scan Tool Reference

Control Module References Programming and Relearning for scan tool information

Circuit/System Verification

1. Ignition ON, with a scan tool command the Headlamps On and OFF. The low beam headlamps should turn ON and OFF when changing between the commanded states.

If the low beam headlamps do not turn ON and OFF when commanded, refer to Headlamps Malfunction Headlamps Malfunction.

2. Ignition ON, park brake released, verify with a scan tool the Park Brake Switch parameter displays Inactive.

If not the specified value, refer to Symptoms - Park Brake Symptoms - Park Brake.

3. Ignition ON, with a scan tool command the DRLs ON and OFF. The low beam headlamps should turn ON and OFF when changing between the commanded states.

If the low beam headlamps do not turn ON and OFF when commanded, refer to Daytime Running Lamps Malfunction.
If the low beam headlamps turn ON and OFF when commanded, refer to Ambient Light Sensor Malfunction.

Circuit/System Testing

Daytime Running Lamps Malfunction
1. Ignition OFF, disconnect the DRL relay.
2. Ignition ON, verify that a test lamp does not illuminate between the control circuit terminal 87 and ground.

If the test lamp illuminates, test the control circuit for a short to voltage.

3. Verify that a test lamp illuminates between the B+ circuit terminal 30 and ground.

If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, test the control circuit terminal 87 for a short to ground. If the circuit tests normal, test or replace the DRL relay.

4. Verify that a test lamp illuminates between the B+ circuit terminal 85 and ground.

If the test lamp does not illuminate, test the B+ circuit for an open/high resistance.

5. Connect a 15A fused jumper wire between the B+ circuit terminal 30 and the control circuit terminal 87. Verify the low beam headlamps are activated.

If the low beam headlamps do not activate, test the control circuit for an open/high resistance.

6. Connect a test lamp between the B+ circuit terminal 85 and the control circuit terminal 86.
7. Command the DRL ON and OFF with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.

If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the BCM.
If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM.

8. If all circuits test normal, test or replace the DRL relay.

Ambient Light Sensor Malfunction
1. Ignition OFF, disconnect the harness connector at the ambient light sensor.
2. Ignition OFF, scan tool OFF, doors CLOSED, test for less than 10 ohms between the appropriate low reference circuit terminal listed below and ground.

* Ambient light sensor low reference circuit terminal B - base
* Ambient light sensor low reference circuit terminal C - uplevel

If greater than the specified range, test the low reference circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM.

3. If all circuits test normal, replace the ambient light sensor.

Repair Instructions

Perform the Diagnostic Repair Verification Verification Tests after completing the diagnostic procedure.

* Ambient Light Sensor Replacement Service and Repair
* Relay Replacement (Attached to Wire Harness) Relay Replacement (Attached to Wire Harness)Relay Replacement (Within an Electrical Center) Relay Replacement (Within an Electrical Center)
* Control Module References Programming and Relearning for BCM replacement, setup, and programming