Compass Malfunction (Mirror)
Compass Malfunction (Mirror)
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions Diagnostic Procedure Instructions provides an overview of each diagnostic category.
Circuit/System Description
The inside rearview mirror (ISRVM) uses 2 magnetic field sensors for compass direction. One sensor is for north and south, the other is for east and west. The ISRVM supplies a signal and low reference to each sensor. As the vehicle travels with or against the earths magnetic pull, there will be a change in voltage on one or both sensors. As a result of the change in voltage, the ISRVM changes the heading on the compass display. The internal fault detection for the compass is handled by the ISRVM.
Reference Information
Schematic Reference
Inside Rearview Mirror Schematics Inside Rearview Mirror Schematics
Connector End View Reference
Component Connector End Views Connector End Views By Name
Description and Operation
Automatic Day-Night Mirror Description and Operation Automatic Day-Night Mirror
Electrical Information Reference
* Circuit Testing Circuit Testing
* Connector Repairs Connector Repairs
* Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections
* Wiring Repairs Wiring Repairs
Scan Tool Reference
Control Module References Programming and Relearning for scan tool information
Circuit/System Verification
1. Ignition ON, compass ON, verify that there is a compass reading on the display.
• If the display is blank, replace the ISRVM.
• If the display shows the letter C or CAL, perform the compass calibration procedure. Refer to Compass Calibration and Magnetic Variance Description and Operation.
2. Verify that the compass reading on the display is correct.
• If not correct, perform the compass magnetic variation adjustment procedure. Refer to Compass Calibration and Magnetic Variance Description and Operation.
3. If the compass display is incorrect, replace the ISRVM.
Repair Instructions
Perform the Diagnostic Repair Verification Verification Tests after completing the diagnostic procedure.
Control Module References Programming and Relearning for ISRVM replacement, setup, and programming