Test Point 13 - Altitude Correction Box
TEST POINT 13Altitude Correction Box
(Tested Below 1 000 Meters Above Sea Level
1. Check CO level.
2. Pull off plug (3) on altitude correction box.
CO test value must not be changed.
3. Bridge plug with a suitable test lead.
CO test value must change in lean direction by about 0.5 to 1.0 %.
4. Connect plug on altitude correction box with power flow tester or ohmmeter.
Specification: infinite ohm (switch open)
Switch of altitude correction box is closed at altitudes higher than 1,000 meters above sea level.
Specification: 0 ohm