Test Point 2
Test point 2
Bleeding condition of the lock control
(post-bleeding the hydraulics of the lock actuation system)
The control quality of the lock depends greatly on the bleeding condition. A relevant test with workshop equipment is not possible. For this reason, post-bleed in cases of doubt.