Test Point 13
Fault Code 13Left door secured but not locked.
1. Pull off Plug I on the alarm control unit.
2. Disconnect plug connection X 11 (driver's side).
3. Check the line from the alarm control unit Plug I pin 30 to the door lock module for ground shorts.
- Ohmmeter on alarm control unit Plug I pin 30 and ground.
Display: infinity Ohms
4. Check the driver's side door lock module switch contact.
- Ohmmeter at plug connection X 11 pin A5 (sleeve side) and ground.
Door locked
Display: infinity Ohms
Door not locked
Display: < 5 Ohms