Test Point 18
Fault Code 18Power window control Ground short.
1. Pull off Plug I on the alarm control unit.
2. Pull off Plug I on the convertible top control unit.
3. Ohmmeter at Plug I alarm control unit pin 18 and ground.
Display: infinity Ohms
If display < 5 Ohms,check the wiring harness for pinches and chafing damage.