Coding
With the Porsche System Tester 2, it is possible to code four defined alarm variants.
1. Country group 1
2. Country group 2
3. Country group 3
4. Country group 4
Alarm output
Country group 1
- Alarm horn, maximum 30 seconds interval.
- Direction indicator lights, maximum 5 minutes interval.
- The interior lights flash asynchronously with the direction indicator lights (if in door contact position).
Country group 2
- Alarm horn maximum 30 seconds continuous tone.
Country group 3
- Alarm horn maximum 4 minutes interval.
- Direction indicator lights maximum 4 minutes interval.
- The interior lights flash asynchronously with the direction indicator lights (it in door con tact position).
Country group 4
- Alarm horn maximum 30 seconds interval.
- Direction indicator lights maximum 5 minutes interval.
- The interior lights flash asynchronously with the direction indicator lights (if in door contact position).
NOTE: If the alarm system is coded to country group 4, deactivation is possible only via the radio remote control and the transponder signal.
The entry delay after opening the door is 10 seconds.