Test Point 16
TEST POINT 16
Hot film mAF sensor
DTC 115
1. Connect voltmeter to control module connector or adapter 9616 (test box) pin 47 (+) and pin 45 (-)
Ignition "ON"
Display: 5 V
2. Connect voltmeter to control module connector or adapter 9616 (test box) pin 17 (+) and pin 45 (-)
Ignition "ON"
Display: 1 V
3. Pull connector off hot film mass air flow sensor
Ignition "ON"
Connect voltmeter to pin 2 (connector side) and engine ground
Display: Battery positive voltage