Test Point 23
TEST POINT 23
Injector valve, cylinder 1, 2, 3, 4, 5, 6
DTC 150 - 155
1. Check voltage supply
Pull off valve connector
Connect voltmeter to connector pin 1 and ground (engine)
Display: Battery positive voltage
2. measure coil resistance
Connect ohmmeter to the contacts of the injection valve
Test value: 12 ± 0.3 ohms
3. Injection driver
Adjust oscilloscope according to the manufacturer's instructions. Connect auxiliary cable (1 684 463 093) from messrs. Bosch between the injection valve and connector. Connect oscilloscope with the auxiliary cable according to the manufacturer's instructions.
Important: The tester cables must not come into contact with ground.
Start engine. The signal shown must be visible if the injection driver is functioning properly and the Tester connections are correct: