Test Point 4
TEST POINT 4
Oxygen sensing range 2 and range 1, cylinders 1 - 3
DTC 26, 27, 28
Fault: Lean limit
mixture is so rich that the control is at its lean limit.
Fault area: Fuel pressure too high or injection valve leaks.
Remedy: 1. Check fuel pressure.
2. Check fuel pressure regulator, vacuum connection and fuel return line.
Fault: Rich limit
mixture is so lean that the control is at its rich limit.
Fault area: - Intake system leaks
- Fuel pressure too low
- Injection valves fouled
- Fuel pump delivery too low
Remedy: 1. Check exhaust system for leaks.
2. Check intake system for leaks.
3. Check fuel pressure.
4. Check fuel pump delivery.
5. Clean injection valves in ultrasound cleaning device or replace.