Test Point 8
Test point 8
Data lead, PCM-instrument cluster
Short to ground
Short to B+
Fault code 27
Short to ground
1. Pull off plug I on the display and operator control unit.
2. Pull off plug III on the instrument cluster.
3. Check lead from plug I pin 20 to plug III pin 6 for short to ground.
Short to B+
1. Pull off plug I on the display and operator control unit.
2. Pull off plug III on the instrument cluster.
3. Check lead from plug I pin 20 to plug III pin 6 for short B+.