DTC 37
DTC 37
37 CAN: Bus off
The status of the CAN controller is checked. The fault is set when the CAN controller is in the "bus off" state.
NOTE: The redundancy transistor is switched off. The setpoint values of the current regulator are set to 0 and all change-over valves are switched off. The control module is then in emergency operation.
Diagnosis conditions
- Ignition on
Possible fault cause
- CAN bus fault communication is completely disturbed
- Short circuit to ground/voltage or in the wiring harness
Affected terminals
Terminal L, H
Diagnosis/Troubleshooting