Oxygen Sensor Ahead of TWC, Bank 1 - Below Limit
P1115
13 Oxygen Sensor Heating Ahead of TWC, Bank 1 - Below Limit
Diagnosis conditions
- Battery voltage between 9.5 V and 16 V
- Time elapsed after engine start-up greater than 10 seconds
Possible fault cause
- Short circuit to ground
Affected terminals
- II/19
Diagnosis/Troubleshooting
NOTE: Do not use contact spray on the connectors to oxygen sensor.
Work Instruction 1 - 3:
NOTE: Do not exchange oxygen sensors ahead of catalytic converter and after catalytic converter.
Oxygen sensors ahead of and after catalytic converter