P1342
P1342
189 Camshaft Adjustment, Bank 1 Output Stage - Open Circuit
Diagnosis conditions
- Engine running
Possible fault cause
- Open circuit in triggering wire
- Open circuit in B+ supply
- Solenoid hydraulic valve faulty
Affected terminals
V/7
Diagnosis/Troubleshooting
NOTE: The wiring for the solenoid hydraulic valve is routed via the connector X 59/1 pin 14.
189 Camshaft Adjustment, Bank 1 Output Stage - Below Limit
Diagnosis conditions
- Engine running
Possible fault cause
- Short to ground triggering wire
- Solenoid hydraulic valve faulty
Affected terminals
V/7
Diagnosis/Troubleshooting
189 Camshaft Adjustment, Bank 1 Output Stage - Above Limit
Diagnosis conditions
- Engine running
Possible fault cause
- Short circuit to B+ triggering wire
Affected terminals
V/7
Diagnosis/Troubleshooting