P1345
P1345
580 Valve Lift Control, Bank 2, Output Stage - Open Circuit
Diagnosis conditions
- Engine running
Possible fault cause
- Open circuit in triggering wire
- Open circuit in B+ supply
- Solenoid hydraulic valve faulty
Affected terminals
III/26
Diagnosis/Troubleshooting
NOTE: The wiring for the solenoid hydraulic valve is routed via the connector X 59/3 pin 5.
580 Valve Lift Control, Bank 2, Output Stage - Below Limit
Diagnosis conditions
- Engine running
Possible fault cause
- Short to ground triggering wire
- Solenoid hydraulic valve faulty
Affected terminals
III/26
Diagnosis/Troubleshooting
580 Valve Lift Control, Bank 2, Output Stage - Above Limit
Diagnosis conditions
- Engine running
Possible fault cause
- Short circuit to B+ triggering wire
Affected terminals
III/26
Diagnosis/Troubleshooting