Capacity Specifications
Distribution Of The Oil Quantity In The Refrigerant Circuit
Total oil quantity 195 ± 15 cb.cm
After suction removal from the system,
the following quantities remain in the
Condenser 2 x 20 cb.cm ca. 40 cb.cm
Evaporator ca. 20 cb.cm
Fluid tank with lines ca. 30 cb.cm
Compressor ca. 50 cb.cm
Circulating oil quantity in the ca. 60 cb.cm
refrigerant circuit
NOTE: In new vehicles, the amount of oil removed by suction is approx. 15 .... 40 cb.cm. Oil removed by suction must be returned to the system.
Refrigerant oil removed from a previously run air-conditioning system may no longer be used (special-category waste).