Test Point 23
TEST POINT 23
W lead (DmE Immobilizer) Short To B+
Fault Code 23
Procedure
1. Voltmeter at alarm system control module plug I pin, 23 and ground. Switch ignition on.
Display: 0 Volts
If no fault can be detected, either the DmE control module or the alarm system control module is faulty.