Fault Code 36
Fault Code 36
Passenger compartment monitoring sensor, short circuit to B+ or faulty
Diagnostic conditions
- Alarm system activated
Possible cause of fault
- Short circuit to voltage in the wiring between the alarm system control module and the passenger compartment monitoring sensor
- Passenger compartment monitoring sensor faulty
Affected terminals
Plug A, terminals 8 and 24
Diagnosis/troubleshooting