Distribution of the Oil Quantity In the Refrigerant Circuit
Distribution Of The Oil Quantity In The Refrigerant Circuit
NOTE:
- Oil removed by suction must be returned to the system.
- Refrigerant oil removed from a previously run air-conditioning system may no longer be used (special-category waste).
- After the refrigerant has been removed by suction and a component has been replaced, the oil quantity must be determined and topped up by the quantity remaining in the removed component.
Oil quantity
Total oil quantity 195 ± 15 cb.cm
After suction removal from the system, the following quantities remain in the:
Condenser (2 x 20 cb.cm ) approx. 40 cb.cm
Evaporator approx. 30 cb.cm
Oil quantity
Fluid tank with lines approx. 30 cb.cm
Compressor approx. 50 cb.cm
Circulating oil quantity approx. 60 cb.cm
in the refrigerant circuit