Accessories - Unintentional Comfort Functions Activation
Technical Information
11(997)
4/06 ENU 9662
Unintentional Activation of Comfort Functions Via The Vehicle Key
NOTE: This Technical Information replaces the TI dated April 20, 2006. Changes/additions compared to the previous Technical Information:
>Changes: "Action Required" and "Work Procedure" sections.
Vehicle Type:
911 Carrera (997)/911 Carrera S (997)/911 Turbo (997)
Model Year:
As of 2005
Concerns:
Remote control (radio remote control)
Situation:
Unintentional activation of comfort functions.
Due to complaints regarding such issues as windows and/or the front lid opening by themselves when the buttons on the vehicle key are pressed unintentionally, for example, the following measures have been implemented on vehicles manufactured as of the specified date of introduction:
- Extension of the delay time after pressing button 2 (until the lid opens) from 471 ms to 700 ms.
- Deactivation of the "Open window" comfort function.
The "Windows" comfort function can be reactivated in the PAS control unit using the PIWIS Tester before the vehicle is returned to the customer, or at a later time if requested by the customer.
Please inform your sales department so that the customer is informed accordingly
Tools:
PIWIS Tester? 9718
Date of Introduction.
Deactivation of the comfort function from February 27, 2006, as of the following VINs:
99 25S 71 6832 Coupe
99 76S 74 2968 Coupe S
99 56S 71 6825 C4
99 86S 74 2977 C4 S
99 56S 75 7321 Cabrio
99 96S 76 8271 Cabrio S
99 96S 75 7323 Cabrio C4
99 76S 76 8270 Cabrio C4 S
Action Required:
- The delay time for "Opening the front lid using the remote control" must be changed and set afterwards using the PIWIS Tester.
As of PIWIS software version 15.0, the delay time can be changed afterwards. In the event of a complaint, the delay time allowed after pressing the button, which is stored in the PAS control unit, can be changed from 471 ms to 700 ms on vehicles manufactured before the specified date of introduction.
As of PIWIS software version 16.0 (available approx. calendar week 37), two additional delay times "long (900 ms)" and "extra long (1100 ms)" will be available as options. We recommend that you use these delay times whenever problems repeatedly occur while the setting "normal (700 ms) recommended" is selected.
- Reactivating "Open window" comfort function:
The "Open window" comfort function can be reactivated using the PIWIS Tester if requested by the customer.
NOTE: If a customer wants to retain the "short" delay time (471 ms) or reactivate the "Open window" comfort function, please inform him/her of the problems that may arise.
Work Procedure:
- Subsequently changing the "lid" delay time:
Using the PIWIS Tester (software version 15.0 or higher), select the setting "normal (700 ms) recommended" or "short (471 ms)" in the PAS control unit -> 'Coding' -> Response time for key-operated buttons 2 and 3' and save this setting by pressing - F8 ".
- Subsequently activating the "Open window" comfort function:
Using the PIWIS Tester:
- Select the setting "active" in the PAS control unit -> 'Coding' -> 'Comfort opening via remote control' and save this setting by pressing - F8",
- select the setting "active" in the PAS control unit -> 'Coding' -> 'Comfort function window' and save this setting by pressing �F8",
- select the setting "Off" in the Driver's door control unit -> 'Coding' -> 'Comfort opening' and save this setting by pressing �F8" and
- select the setting "Off" in the Passenger's door control unit -> 'Coding' -> 'Comfort opening' and save this setting by pressing - F8".