87471900 Removing and installing evaporator-fluid tank line


WM 874719 Removing and installing evaporator-fluid tank line

Technical values





Preliminary work

Preliminary work line condenser-fluid tank

Draining refrigerant. -> 870317 Draining and filling in refrigerant - section on "draining" Service and Repair

Removing cowl panel cover. -> 508719 Removing and installing cowl panel cover - section on "removing" Service and Repair
Removing the battery. -> 270619 Removing and installing battery - section on "Removing" 27061900 Removing and installing battery

Removing the condenser-fluid tank line

Information

Before re-installing the component, check the O-rings of the refrigerant lines for damage and replaced them if necessary.

Wet the O-rings of the refrigerant lines with refrigerant oil.

Do not open the plugs for the lines and connections until shortly before installation.

Close off all lines and connections using suitable plugs during removal.





Installation location line condenser-fluid tank

1. Unscrew fastening nut -1-.





Unscrewing fastening nuts

2. Remove the holder for the two refrigerant lines and pull the refrigerant line condenser-fluid tank out of the expansion valve.
3. Unscrew the fastening nut -2- for the refrigerant line condenser-fluid tank in front of the fluid tank, detach the line from the holder and pull out from under the water hoses for the heat exchanger.





Taking out refrigerant line

Installing the condenser-fluid tank line

Information

Before re-installing the component, check the O-rings of the refrigerant lines for damage and replaced them if necessary.

Wet the O-rings of the refrigerant lines with refrigerant oil.

Do not open the plugs for the lines and connections until shortly before installation.

Close off all lines and connections using suitable plugs during removal.

1. Lay the refrigerant line under the heat exchanger hoses and screw down on line to fluid tank -2- with fastening nut. => Tightening torque: 20 Nm (15 ftlb.)





Fastening nut on line fluid tank

2. Clip line into the holder.
3. Position holder for refrigerant lines and secure with the fastening nut -1-. => Tightening torque: 6 Nm (4.5 ftlb.)





Screwing in fastening nuts

Subsequent work

Subsequent work line condenser-fluid tank

Installing battery. -> 270619 Removing and installing battery - section on "Installing" 27061900 Removing and installing battery

Filling in refrigerant. -> 870317 Draining and filling in refrigerant Service and Repair

Installing cowl panel cover. -> 508719 Removing and installing cowl panel cover - section on "Installing" Service and Repair